Screws Securing Rear Side Of I/H Left Unit - Epson Stylus Pro 4400 Service Manual

Hide thumbs Also See for Stylus Pro 4400:
Table of Contents

Advertisement

EPSON Stylus Pro 4400/4450/4800/4880/4880C
10. Remove the six screws securing the "I/H Left Unit" to the pinter.
C.B.S. 3x8:
6 pcs.
11. Disconnect the FFCs from the CN1 to CN3 connectors on the "C593_SUB-
D Board", and pull out the FFCs toward the left side of the printer frame.
12. Peel off the acetate tape that secures the front side of the "I/H Left Unit".
13. Remove the four screws securing rear side of "I/H Left Unit".
(Refer to Figure 4-130.)
C.B.S. 3x6:
4 pcs.
Harnesses are routed through the area of screws as shown
by the arrows in
Figure
When installing the unit, install it without pinching
harnesses by the screw after removing the "Cover, Motor,
PF".
Refer to "4.2.6.4 ASF Phase Sensor" (p263).
Disassembly & Assembly
4-130.
Disassembly Procedures
Step 12
Acetate Tape
C.B.S. 3x8
Figure 4-129. I/H Left Unit Front Side_2
Cover, Motor, PF
C.B.S. 3x6
Figure 4-130. Screws Securing Rear Side of I/H Left Unit