18. Pull the "I/H Right Unit" forward from the printer following the order below
while pulling the "Harness, CSIC" and "I/H Lever Sensor (Right)" harness
from the hole in the frame.
(Refer to Figure 4-150.)
18-1.
To avoid interference of the printer frame hole and "I/H Right Unit"
shaft, shift the "I/H Right Unit" to the left.
18-2.
With the right side of the "Paper Eject Unit" lifted up, pull the "I/H
Right Unit" forward from the printer.
The four grounding springs on the top of the "I/H Right Unit"
make contact with the printer frame, so install the "I/H Right
Unit" while lightly holding down the grounding springs so as
not to deform them.
19. Pick up and release the two hooks securing the "I/H Lever Sensor (Right)"
and then remove the "I/H Lever Sensor (Right)".
20. Disconnect connector from "I/H Lever Sensor (Right)".
(Refer to Figure 4-151.)
Disassembly & Assembly
Grounding Springs
(Refer to Figure 4-151.)
Disassembly Procedures
Paper Eject Unit
2
3
Figure 4-150. I/H Right Unit Removal
I/H Lever Sensor (Right)
Hooks
Figure 4-151. I/H Lever Sensor (Right) Removal
Revision C
Pull harness through this hole
1
Step 18-1
Shaft and Frame interference
Connector