Theory of Operation
Power Switch
Main Fan
Electrically Erasable Programmable Read-Only Memory (EEPROM) Board
Humidity Sensor
Interlock Switch
Low-Voltage Power Supply (LVPS)
2-38
The Power Switch turns the printer AC Power Supply On/Off.
The Main Fan removes heat from the printer to prevent overheating.
The EEPROM Board stores the printer unique information. Information on the
EEPROM Board is also stored on the Machine Control Unit (MCU) Board.
The Humidity Sensor reads the humidity and temperature within the printer.
The Interlock Switch is a switch that cuts the +24 VDC power supply to the
HVPS or Motor upon the opening of the Front Cover.
Two types of LVPS are available: 100/120V and 230V. The LVPS supplies AC
power from the power source to the Fuser Heater; the LVPS also generates
and supplies stable low-voltage DC power used for the logic circuit. The LVPS
contains a control circuit for the heater of the Fuser, in addition to the power
circuit.
s6280-085
Phaser 6280 Color Laser Printer Service Manual