9.2.2

Mode group RESET

Function
A mode group Reset is requested via a mode group-specific NC/PLC interface signal:
DB11 DBX0.7 = 1 (mode group reset)
Effect
Effect on the channels of mode group:
Part program preparation (preprocessing) is stopped.
All axes and spindles are decelerated to zero speed according to their acceleration curves without contour
violation.
Any auxiliary functions not yet output to the PLC are no longer output.
The preprocessing pointers are set to the interruption point, and the block pointers are set to the beginning of
the appropriate part programs.
All initial settings, (e.g. the G functions), are set to the parameterized values.
All alarms with "Channel reset" criterion are canceled.
If all the channels of the mode group are in reset state, then:
All alarms with "Mode group reset" cancel criterion are canceled.
The NC/PLC interface indicates completion of the mode group Reset and the mode group's readiness to
operate:
DB11 DBX6.7 (all channels in the reset state)
DB11 DBX6.3 = 1 (mode group ready)
Basic Functions
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
K1: Mode group, channel, program operation, reset response
9.2 Mode group (MG)
483