8.17
Examples
8.17.1
Extension of predefined auxiliary functions
Task
Parameter assignment of auxiliary functions M3, M4, and M5 for the second spindle of the channel
Parameter assignment: M3
Requirements:
•
Machine data index: 0 (first user-defined auxiliary function)
•
auxiliary function group: 5
•
Type and value: M3 (spindle right)
•
Address extension: 2 as appropriate for the 2nd spindle of the channel
•
Output behavior:
-
Output duration one OB1 cycle (normal acknowledgment)
-
Output prior to motion
Parameter assignment:
MD22000 $MC_AUXFU_ASSIGN_GROUP[ 0 ]
MD22010 $MC_AUXFU_ASSIGN_TYPE [ 0 ]
MD22020 $MC_AUXFU_ASSIGN_EXTENSION [ 0 ] = 2
MD22030 $MC_AUXFU_ASSIGN_VALUE [ 0 ]
MD22035 $MC_AUXFU_ASSIGN_SPEC [ 0 ]
Parameter assignment: M4
Requirements:
•
Machine data index: 1 (second user-defined auxiliary function)
•
auxiliary function group: 5
•
Type and value: M4 (spindle left)
•
Address extension: 2 as appropriate for the 2nd spindle of the channel
•
Output behavior:
-
Output duration one OB1 cycle (normal acknowledgment)
-
Spindle response following acknowledgment
-
Output during motion
Basic Functions
Function Manual, 09/2011, 6FC5397-0BP40-2BA0
H2: Auxiliary function outputs to PLC
= 5
= "M"
= 3
= 'H21'
8.17 Examples
467