(4) Detaching and refitting the high voltage PWB 1

Procedure
1. Remove the power source PWB (see
page 1-5-56).
2. Remove the main drive unit (see page
1-5-73).
3. Remove five connectors from high volt-
age PWB.
4. Remove eight screws.
5. Unhook two hooks of PWB spacer and
then remove the high voltage PWB 1.
6. Check or replace the high voltage PWB
1 and refit all the removed parts.
High voltage
PWB 1
Connectors
YC4
YC18
High voltage
PWB 1
Screws
Screw
Screw
PWB spacer
Screws
1-5-59
2LK/2LN/2LM/2LC
Connectors
YC3
YC10
YC11
Connector
Figure 1-5-92
Screws
High voltage PWB 1
Figure 1-5-93