Item No.
U131
Setting: [Mode]
1. Select the item to be set.
Manual
Auto
Initial setting: Auto
2. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
U132
Replenishing toner forcibly
Description
Replenishes toner forcibly until the toner sensor output value reaches the toner feed start level.
Purpose
Used when the toner empty is detected frequently.
Method
1. Press the start key.
2. Select [Execute].
3. Press the start key.
Toner is replenished until the toner sensor output value reaches the toner feed start level.
Supply(C)
Supply(M)
Supply(Y)
Supply(K)
Sensor(C)
Sensor(M)
Sensor(Y)
Sensor(K)
4. To stop operation, press the stop key.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Display
Toner sensor control voltage manual adjustment
Toner sensor control voltage auto adjustment
Display
Toner feed start level (cyan)
Toner feed start level (magenta)
Toner feed start level (yellow)
Toner feed start level (black)
Toner sensor output value (cyan)
Toner sensor output value (magenta)
Toner sensor output value (yellow)
Toner sensor output value (black)
Description
Description
Description
1-3-88
2LK/2LN/2LM/2LC