Item No.
U161
Setting: [Print]
1. Select the item to be set.
2. Change the setting value using the +/- keys.
Display
Full Speed
(Center)
Duplex Shift
(Center)
3. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
U163
Resetting the fuser problem data
Description
Resets the detection of a service call code indicating a problem in the fuser section.
Purpose
To prevent accidents due to an abnormally high fuser temperature.
Method
1. Press the start key.
2. Press [Execute].
3. Press the start key. The fuser problem data is initialized.
4. Turn the main power switch off and on. Allow more than 5 seconds between Off and On.
U167
Checking/clearing the fuser count
Description
Displays and clears the fuser count for checking.
Purpose
To check or clear the fuser count after replacement of the fuser unit. Also to clear the counts after
replacing unit.
Method
1. Press the start key. The fuser count is displayed.
Cnt
Clearing
1. Press [Clear].
2. Press the start key. The count is cleared.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Temperature at maximum print speed
(Center)
Temperature at duplex printing
(Center)
Display
Fuser unit count value
Description
Description
Description
1-3-100
2LK/2LN/2LM/2LC
Setting
Initial
range
setting
130 to 200(°C) 165
100 to 200(°C) 1