Kyocera TASKalfa 3050ci Service Manual page 304

Hide thumbs Also See for TASKalfa 3050ci:
Table of Contents

Advertisement

Code
Contents
7244
Broken developer thermis-
tor Y wire
The sensor input sampling is
greater than 255.
7251
Short-circuited developer
thermistor K
The sensor input sampling is
less than 0.
7252
Short-circuited developer
thermistor C
The sensor input sampling is
less than 0.
7253
Short-circuited developer
thermistor M
The sensor input sampling is
less than 0.
7254
Short-circuited developer
thermistor Y wire
The sensor input sampling is
less than 0.
Causes
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Developer unit Y and front PWB (YC15)
Front PWB (YC2) and engine PWB (YC10)
Defective devel-
Replace developer unit Y (see page 1-5-36).
oper thermistor Y.
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-54).
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Developer unit K and front PWB (YC9)
Front PWB (YC2) and engine PWB (YC10)
Defective devel-
Replace developer unit K (see page 1-5-36).
oper thermistor K.
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-54).
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Developer unit C and front PWB (YC13)
Front PWB (YC2) and engine PWB (YC10)
Defective devel-
Replace developer unit C (see page 1-5-36).
oper thermistor C.
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-54).
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Developer unit M and front PWB (YC11)
Front PWB (YC2) and engine PWB (YC10)
Defective devel-
Replace developer unit M (see page 1-5-
oper thermistor M.
36).
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-54).
Defective connec-
Reinsert the connector. Also check for conti-
tor cable or poor
nuity within the connector cable. If none,
contact in the con-
replace the cable.
nector.
Developer unit Y and front PWB (YC15)
Front PWB (YC2) and engine PWB (YC10)
Defective devel-
Replace developer unit Y (see page 1-5-36).
oper thermistor Y.
Defective engine
Replace the engine PWB and check for cor-
PWB.
rect operation (see page 1-5-54).
1-4-64
2LK/2LN/2LM/2LC
Check procedures/
corrective measures