Kyocera TASKalfa 3050ci Service Manual page 198

Hide thumbs Also See for TASKalfa 3050ci:
Table of Contents

Advertisement

Item No.
U411
Method: [Table (Chart2)]
1. Enter the target values which are shown on the specified original (P/N: 302FZ56990) execut-
ing maintenance item U425.
2. Set a specified original (P/N: 302FZ56990) on the platen.
3. Enter maintenance item U411.
4. Select [Target].
5. Select [U425] and press the start key.
6. Select [Table (Chart2)].
7. Select the item.
All
Input
C.A.
MTF
Gamma
Matrix
8. Press the start key. Auto adjustment starts.
* : When automatic adjustment has normally completed, [OK] is displayed. If a problem
occurs during auto adjustment, error code is displayed and operation stops. Should this
happen, determine the details of the problem and repeat the procedure from the begin-
ning.
Method: [DP FaceUp (Chart2)]
1. Measure the leading edge, main scanning, and auxiliary scanning of the specified original (P/
N: 302AC68243) and enter the values by executing maintenance item U425.
2. Set a specified original (P/N: 302AC68243) on the DP.
Cut the trailing edge of the original.
3. Enter maintenance item U411.
4. Select [Target].
5. Select [U425] and press the start key.
6. Select [DP FaceUp (Chart2)].
7. Select [INPUT].
Input
Display
Executing the all scanner adjustment
Executing the adjustment for magnification, leading edge tim-
ing and center line
Executing the adjustment for chromatic aberration filter
Executing the adjustment for MTF filter
Executing the adjustment for input gamma
Executing the adjustment for matrix
Display
Executing the adjustment in the DP scanning section (first
side) for magnification, leading edge timing and center line
Description
Description
74 ± 1 mm
Figure 1-3-29
Description
1-3-156
2LK/2LN/2LM/2LC
5 mm
149 ± 1 mm

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Taskalfa 3550ciTaskalfa 4550ciTaskalfa 5550ci