Item No.
U208
Setting the paper size for the side feeder
Description
Sets the size of paper used in side feeder.
Purpose
To change the setting when installing the side feeder or the size of paper used in the side feeder
is changed.
Setting
1. Press the start key.
2. Select the paper size (A4, B5 or Letter).
Initial setting: Letter (Inch specifications)
3. Press the start key. The setting is set.
4. Turn the main power switch off and on. Allow more than 5 seconds between Off and On.
U211
Setting the presence or absence of the job separator
Description
Sets the presence or absence of the inner job separator.
Purpose
To run this maintenance item if the inner job separator is installed.
Method
1. Press the start key.
2. Select [Inner Job Separator].
3. Select On or Off.
On
Off
Initial setting: Off
4. Press the start key. The setting is set.
5. Turn the main power switch off and on. Allow more than 5 seconds between Off and On.
A4 (Metric specifications)
Display
The inner job separator is installed
The inner job separator is not installed