(3) Detaching and refitting the LSU
Procedure
1. Remove the conveying unit (see page
1-5-39).
2. Remove the left upper cover (see page
1-5-49).
3. Remove the toner filter.
4. Remove the left filter cover and the left
filter.
5. Remove two transfer belt filters.
6. Remove the left cover lid.
7. Open the front cover and remove screw
A.
8. Remove three screws B and then
remove the left cover.
9. Remove four screws and then remove
the LSU retainer.
Toner filter
Left cover
Left filter
1-5-25
2LK/2LN/2LM/2LC
Transfer belt filters
Screw B
Left cover lid
Left filter cover
Figure 1-5-41
LSU retainer
Screws
Figure 1-5-42
Screw A
Screws B
Screws