Connector
Pin
YC10
1
3.3V2
Connected to
2
EEP_SCL1
drum unit M
3
EEP_SDA1
4
GND
5
DRM_ADR0_M
6
DRM_ADR1_M
7
24V
8
ERS_M_REM
YC11
1
TPD_TEMP_M
Connected to
2
DLP_VCONT_M_
developer
1
unit M
3
TPD_M_1
4
TN_CLK_M
5
GND
6
DLP_ADR1_M
7
DLP_ADR0_M
8
EEP_SDA1
9
EEP_SCL1
10
3.3V2
11
3V
12
VIB_MOT
YC12
1
3.3V2
Connected to
2
EEP_SCL1
drum unit C
3
EEP_SDA1
4
GND
5
DRM_ADR0_C
6
DRM_ADR1_C
7
24V
8
ERS_C_REM
Signal
I/O
O
3.3 V DC
O
0/3.3 V DC (pulse) EEPROM clock signal
I/O
0/3.3 V DC (pulse) EEPROM data signal
-
-
-
-
-
-
O
24 V DC
O
0/24 V DC
I
Analog
O
0/3.3 V DC
I
Analog
O
0/3.3 V DC (pulse) Clock signal
-
-
-
-
-
-
I/O
0/3.3 V DC (pulse) EEPROM data signal
O
0/3.3 V DC (pulse) EEPROM clock signal
O
3.3 V DC
O
3.3 V DC
O
0/24 V DC
O
3.3 V DC
O
0/3.3 V DC (pulse) EEPROM clock signal
I/O
0/3.3 V DC (pulse) EEPROM data signal
-
-
-
-
-
-
O
24 V DC
O
0/24 V DC
Voltage
3.3 V DC power to DRPWB-M
Ground
Not used
Not used
24 V DC power to CL-M
CL-M: On/Off
Developer thermistor M detection sig-
nal
DEVPWB-M control signal
DEVPWB-M detection signal
Ground
Not used
Not used
3.3 V DC power to DEVPWB-M
3.3 V DC power to VM-M
VM-M: On/Off
3.3 V DC power to DRPWB-C
Ground
Not used
Not used
24 V DC power to CL-C
CL-C: On/Off
2-3-62
2LK/2LN/2LM/2LC
Description

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Taskalfa 3550ciTaskalfa 4550ciTaskalfa 5550ci

Table of Contents