Item No.
U140
Setting: [Mag AC]
1. Select the item to be set.
2. Change the setting value using the +/- keys or numeric keys.
Display
C
M
Y
K
B/W
3. Press the start key. The value is set.
Setting: [Sleeve Freq]
1. Select the item to be set.
2. Change the setting value using the +/- keys or numeric keys.
Display
Normal
B/W
Half
3/4
3. Press the start key. The value is set.
Setting: [Sleeve Duty]
1. Select the item to be set.
2. Change the setting value using the +/- keys or numeric keys.
Display
Normal
B/W
3. Press the start key. The value is set.
Description
Developer magnet roller AC bias for
cyan
Developer magnet roller AC bias for
magenta
Developer magnet roller AC bias for
yellow
Developer magnet roller AC bias for
black
Developer magnet roller AC bias in
black/white mode
Description
Developer sleeve roller frequency
Developer sleeve roller frequency in
black/white mode
Developer sleeve roller frequency (half speed) 0 to 6200
Developer sleeve roller frequency at 3/4 times
of line speed
Description
Developer sleeve roller duty
Developer sleeve roller duty in black/
white mode
1-3-93
Description
Setting
range
0 to 255
0 to 255
0 to 255
0 to 255
0 to 255
Setting
range
0 to 99
0 to 99
2LK/2LN/2LM/2LC
Initial
setting
30 ppm/
45 ppm/
35 ppm
55 ppm
101
178
101
178
101
178
101
178
178
178
Setting
Initial
range
setting
0 to 6200
5276
0 to 6200
5344
5276
0 to 6200
5276
Initial
setting
30 ppm/
45 ppm/
35 ppm
55 ppm
37
68
68
68