Item No.
U140
Setting: [Magnification]
1. Select the item to be set.
2. Change the setting value using the +/- keys or numeric keys.
Display
C
M
Y
K
3. Press the start key. The value is set.
Method: [Type]
1. Select Mode1 or Mode2.
Mode1
Mode2
Initial setting: Mode1
2. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
U148
Setting drum refresh mode
Description
Selects the mode used in drum refreshing
Purpose
Change settings when drum refreshing is too frequently executed.
Setting
1. Press the start key.
2. Select the mode.
Display
Mode
* : 0: Off / 1: Short / 2: Standard / 3: Long
3. Press the start key. The setting is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Target bias value (cyan)
Target bias value (magenta)
Target bias value (yellow)
Target bias value (black)
Display
Execute AC calibration by normal bias control
If print density is low in an installation at high altitude, execute
calibration by fixing the bias potential.
Setting drum refresh mode
Description
Description
Description
Description
1-3-95
2LK/2LN/2LM/2LC
Setting
Initial
range
setting
-10 to 5
0
-10 to 5
0
-10 to 5
0
-10 to 5
0
Setting
Initial
range
setting
0 to 3
2