(4) Detaching and refitting the MP tray paper feed unit
Procedure
1. Pull the conveying unit out.
2. Open the MP tray.
3. Remove four screws.
4. Unhook seven hooks and then remove
the DU cover assembly.
Conveying unit
Figure 1-5-17
Hook
DU cover
assembly
Figure 1-5-18
1-5-11
2LK/2LN/2LM/2LC
Screw
Screw
MP tray
Right cover
Hooks
Hooks