(3) Detaching and refitting the high voltage PWB

Procedure
1. Remove the developer unit (See page
1-5-27).
2. Remove the drum unit (See page 1-5-
28).
3. Remove the cassette (See page 1-5-6).
4. Remove the left cover and right cover
(See page 1-5-3).
5. Remove the power source PWB (See
page 1-5-40).
6. Turn the machine with the front side up.
7. Remove the stopper.
8. Remove the DU holder.
9. Pull the DU bush out.
10. Remove the DU cover assembly.
DU cover
assembly
1-5-43
2MH/2MJ/2MK/2ML
DU holder
Figure 1-5-64
DU bush
Figure 1-5-65
Stopper