Checking Lsu Cleaning Operation - Kyocera TASKalfa 3050ci Service Manual

Hide thumbs Also See for TASKalfa 3050ci:
Table of Contents

Advertisement

Item No.
U469
Method: [Belt Initialize]
1. Select [Execute].
2. Press the start key. Transfer belt speed correction starts.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
U474

Checking LSU cleaning operation

Description
Provides cleaning LSU by means of the LSU cleaning motor. Also, the cleaning cycle can be
adjusted.
Method
1. Press the start key.
2. Select the item.
Execute
Cycle
Method: [Execute]
1. Press the start key. Cleaning the LSU slit glass.
Setting: [Cycle]
1. Change the setting value using +/- keys.
Display
Cycle
The setting can be changed by 1000 per step.
2. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Display
Executing the cleaning operation
Setting the cleaning cycle
Cleaning cycle
Description
Description
Description
1-3-177
2LK/2LN/2LM/2LC
Setting
Initial
range
setting
0 to 5000
1000

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Taskalfa 3550ciTaskalfa 4550ciTaskalfa 5550ci

Table of Contents