Detaching And Refitting The High Voltage Pwb - Kyocera FS-6025MFP/B Service Manual

Hide thumbs Also See for FS-6025MFP/B:
Table of Contents

Advertisement

5. Remove four FFCs from the operatioon
panel PWB main.
6. Remove four screws and then remove
the operation panel PWB main.
7. Check or replace the operation panel
PWB main and refit all the removed
parts.

(5) Detaching and refitting the high voltage PWB

Procedure
1. Remove the rear cover, inner tray and
eject rear cover.
(See page 1-5-5,1-5-6 and 1-5-8)
2. Remove the FFC from the high voltage
PWB.
3. Remove four screws and then remove
the high voltage PWB.
4. Check or replace the high voltage PWB
and refit all the removed parts.
Operation panel
PWB main
Screw
Screw
Figure 1-5-63
High voltage PWB
Figure 1-5-64
1-5-36
FFCs
Screw
Screw
FFC
High voltage
PWB
Connector(back side)
Screw
Screw
2K3/2L3
Screw
Screw

Advertisement