5.3.5 Communication with other machines or PLCs
The digital I/O can be used to communicate with other equipment if a common GND
(0V) is established and if the machine uses PNP technology, see below.
5.3.6 General purpose analog I/O
The analog I/O interface is the green terminal. It can be used to set or measure voltage
(0-10V) or current (4-20mA) from and to other equipment.
The following is recommended to achieve the highest accuracy.
Input modes can be selected in the GUI, see part II. The electrical specifications are
shown below.
UR3/CB3
24V
DI0
24V
DI1
24V
DI2
24V
DI3
Digital Inputs
Digital Outputs
24V
24V
0V
DI0
DI4
DO0
24V
24V
0V
DI1
DI5
DO1
24V
24V
0V
DI2
DI6
DO2
24V
24V
0V
DI3
DI7
DO3
• Use the AG terminal closest to the I/O. The pair share a common mode filter.
• Use the same gnd (0V) for equipment and control box. The analog I/O is not
galvanically isolated from the control box.
• Use a shielded cable or twisted pairs. Connect the shield to the "GND" terminal
at the terminal called "Power".
• Use of equipment that works in current mode. Current signals are less sensitive
to interferences.
Digital Inputs
24V
DI4
24V
DI5
24V
DI6
24V
DI7
0V
A B
DO4
0V
DO5
0V
DO6
0V
DO7
I-38
5.3 Controller I/O
Digital Inputs
Digital Outputs
24V
24V
0V
0V
DI0
DI4
DO0
DO4
24V
24V
0V
0V
DI1
DI5
DO1
DO5
24V
24V
0V
0V
DI2
DI6
DO2
DO6
24V
24V
0V
0V
DI3
DI7
DO3
DO7