Error Codes

Code
Detection description
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the following
remedies.
(1) Check that the heater resistance measured between
1PIN and 2PIN of the cable (J101) on the DC Controller
Board is in the following range. Replace the Fixing
Fixing Assembly does
Assembly when the resistance value is abnormal.
E000
0000
not start up within
[1] 120 V machine - Heater resistance: 16.0 Ω ±7%
specified time.
[2] 230 V machines - Heater resistance: 53.8 Ω ±7%
(2) Check the connection of connector (J101) on the DC
Controller Board.
(3) Check the connection of connector (J552) on DC
Controller Board.
(4) Replace the Fixing Assembly.
(5) Replace the DC Controller Board.
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the following
remedies.
(1) Check that the heater resistance measured between
1PIN and 2PIN of the cable (J101) on the DC Controller
Board is in the following range. Replace the Fixing
Assembly when the resistance value is abnormal.
Abnormal high-
E001
0000
[1] 120 V machine - Heater resistance: 16.0 Ω ±7%
temperature detection
[2] 230 V machines - Heater resistance: 53.8 Ω ±7%
(2) Check the connection of connector (J101) on the DC
Controller Board.
(3) Check the connection of connector (J552) on DC
Controller Board.
(4) Replace the Fixing Assembly.
(5) Replace the DC Controller Board.
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the following
remedies.
(1) Check that the heater resistance measured between
1PIN and 2PIN of the cable (J101) on the DC Controller
Board is in the following range. Replace the Fixing
Assembly when the resistance value is abnormal.
Abnormal low-
E003
0000
[1] 120 V machine - Heater resistance: 16.0 Ω ±7%
temperature detection
[2] 230 V machines - Heater resistance: 53.8 Ω ±7%
(2) Check the connection of connector (J101) on the DC
Controller Board.
(3) Check the connection of connector (J552) on DC
Controller Board.
(4) Replace the Fixing Assembly.
(5) Replace the DC Controller Board.
7
Error Codes > Error Codes
Remedy
7
Error Codes > Error Codes
Code
Detection description
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the following
Fixing power supply
E004
0000
remedies.
drive circuit error
(1) Replace the DC Controller Board.
(2) Replace the Fixing Assembly.
When the same error repeatedly occurs after several
Error detection on any
times of turning the power OFF/ON, execute the following
of scanner motor, laser
E100
0001
remedies.
unit, and BD detection
(1) Replace the Laser Scanner Unit.
at scanner area.
(2) Replace the DC Controller Board.
ROM read/write error
When the same error repeatedly occurs after several
(Error in storing each
times of turning the power OFF/ON, execute the following
E196
2000
setting values for user
remedies.
mode / service mode /
(1) Update the set of the Controller Firmware
factory mode)
(2) Replace the Main Controller Board.
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the following
remedies.
(1) Check the connection of Flat Cable between Main
Contact Sensor HP
E202
0002
Controller Board (J5) and Contact Sensor.
error, Failure in return
(2) Replace the Flat Cable between Main Controller Board
(J5) and Contact Sensor.
(3) Replace the Contact Sensor.
(4) Replace the Main Controller Board.
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the following
remedies.
Light intensity of a lamp
(1) Check the connection of Flat Cable between Main
E225
0001
is less or equal to the
Controller Board (J5) and Contact Sensor.
criteria
(2) Replace the Flat Cable between Main Controller Board
(J5) and Contact Sensor.
(3) Replace the Contact Sensor.
(4) Replace the Main Controller Board.
When the same error repeatedly occurs after several
times of turning the power OFF/ON, execute the following
remedies.
(1) Check the connection of Flat Cable between Main
Insufficient light intensity
E301
0001
Controller Board (J5) and Contact Sensor.
in shading
(2) Replace the Flat Cable between Main Controller Board
(J5) and Contact Sensor.
(3) Replace the Contact Sensor.
(4) Replace the Main Controller Board.