Disassembly/Assembly > Controller System (Duplex Model) > Removing the Main Controller PCB (Duplex Model) > Procedure
■ Procedure
1) Disconnect all the Flat Cables [1] and connectors [2] installed on the Main Controller PCB.
[1]
2) Remove the Main Controller PCB [1].
• 1 Screw [2]
• 5 Screws (black TP) [3]
6x
[2]
4
Disassembly/Assembly > Controller System (Duplex Model) > Removing the Main Controller PCB (Duplex Model) > Procedure
[2]
F-4-292
[3]
[1]
[3]
F-4-293
NOTE:
The layout of the connectors on the Main Controller PCB is shown below.
J1
J2
J10
J14
J600
J6
J22
J903
J No.
J No.
Symbol
J1
J401
UNIT14
Control Panel PCB
J2
J1601
CIS
CIS Sensor
J3
J902
UNIT2
Engine Controller PCB
J4
J1
UNIT13
Wireless LAN PCB
J6
-
-
-
J7
J1402
PS2
Original Sensor
J7
J1403
PS3
Original Edge Sensor
J7
J1406
PS4
Original Sensor
J7
J1407
PS5
Original Edge Sensor
J8
-
SL3
DADF Solenoid Unit
J10
J102
FM2
Edge Right Cooling Fan
J10
J103
FM3
Edge Left Cooling Fan
J11
-
M3
Flatbed Motor Unit
J12
J1401
M4
DADF Motor Unit
J12
J1401
M5
SADF Motor Unit
J14
-
-
USB
J22
-
-
-
J600
-
-
LAN
J901
J1204
UNIT16
FAX NCU PCB
J903
J1201
UNIT16
FAX NCU PCB
J904
-
SP1
Speaker
4-106
J3
J8
J7
J11
J12
J4
J904
J901
F-4-294
Name
Remarks
WIFI Model
DADF Model
DADF Model
SADF Model
SADF Model
DADF Model
DADF Model
SADF Model
FAX Model
FAX Model
FAX Model
T-4-41
4-106

Advertisement

Table of Contents