4
Disassembly/Assembly > Controller System (Simplex Model) > Removing the Main Controller PCB (Simplex Model) > After Replacing
NOTE:
The layout of the connectors on the Main Controller PCB is shown below.
J1
J2
J14
J600
J6
J22
J903
J No.
J No.
Symbol
J1
J401
UNIT14
Control Panel PCB
J2
J1601
CIS
CIS Sensor
J3
J902
UNIT2
Engine Controller PCB
J4
J1
UNIT13
Wireless LAN PCB
J6
-
-
-
J7
J1406
PS4
Original Sensor
J7
J1407
PS5
Original Edge Sensor
J11
-
M3
Flatbed Motor Unit
J12
J1401
M5
SADF Motor Unit
J14
-
-
USB
J22
-
-
-
J600
-
-
LAN
J901
J1204
UNIT16
FAX NCU PCB
J903
J1201
UNIT16
FAX NCU PCB
J904
-
SP1
Speaker
4
Disassembly/Assembly > Controller System (Simplex Model) > Removing the Main Controller PCB (Simplex Model) > After Replacing
J3
J7
J11
J12
J4
J904
J901
F-4-468
Name
Remarks
Wifi Model
SADF Model
SADF Model
SADF Model
FAX Model
FAX Model
FAX Model
T-4-49
■ After Replacing
1) After replacing the PCB, enter the serial number in "Location " of System Management
Settings from remote UI or local UI, and confirm the serial number.
2) Check that OK is displayed in COPIER > OPTION > SERIAL > SN-MAIN.
• For the detailed procedure, refer to the chapter on service mode.
3) COPIER > OPTION > BODY > LOCALE
To set country group.
1: Japan
2: North America
3: Korea
4: China
5: Taiwan
6: Europe
7: Asia
8: Oceania
Setting range: 1 - 8 (Service part default value: 2)
4) Execute the following service mode to enable this setting.
COPIER > FUNCTION > CLEAR > ALL
5) If the user has printed the user data list and saved the address book before the
replacement, ask the user to return the settings back to the original values.
• Ask the user to load the address book from remote UI.
1. Start remote UI and log in in administrator mode.
2. [Settings/Registration] > [Import/Export] > [Import]
3. Select the address book file to be imported, and click [Start Importing].
4. Click [OK].
4-160