Canon i-SENSYS MF229dw Service Manual page 183

Table of Contents

Advertisement

4
Disassembly/Assembly > Image Formation System (Duplex Model) > Removing the Transfer Roller (Duplex Model) > Procedure
3) Hold both ends of the shaft [1] of the Transfer Roller, and remove the Transfer Roller [2].
[1]
[2]
CAUTION:
Be sure that the bushing [1] is facing the correct direction when assembling.
[1]
4
Disassembly/Assembly > Image Formation System (Duplex Model) > Removing the Transfer Roller (Duplex Model) > Procedure
NOTE: How to assemble the Transfer Roller
Be sure to assemble it by aligning the spring [1] with the boss [2].
F-4-342
F-4-343
[1]
[2]
F-4-344
4-121
4-121