1) Change the orientation of the Control Panel Unit [1] so that it is facing down.
CAUTION:
Be sure to put a piece of paper [2] and place the Control Panel Unit [1] on it carefully so
as not to damage it.
[1]
2) Remove the Harness Cover [1].
• 4 Claws [2]
[2]
[2]
4x
[1]
4
Disassembly/Assembly > Original Exposure/Feed System (DADF Model) > Disconnecting the DADF Unit + Reader Unit > Procedure
[2]
F-4-48
3) Free the harness [1] from the guide [A].
NOTE: How to Assemble the Harness Cover
As for the guide [A], be sure to install the Harness Cover after routing the harness [2]
F-4-47
on the back side of the Flat Cable [1].
[1]
1x
[2]
[2]
[1]
4-31
[A]
F-4-49
[A]
[1]
F-4-50