Removing The Contact Image Sensor (Copyboard Model) - Canon i-SENSYS MF229dw Service Manual

Table of Contents

Advertisement

4
Disassembly/Assembly > Original Exposure/Feed System (Copyboard Model) > Removing the Contact Image Sensor (Copyboard Model) > Procedure
4) Remove the Copyboard Glass [1].
CAUTION:
• Do not lose the 2 spacers [1] of the Contact Image Sensor Unit.
• Do not touch the document reading part [A] of the Contact Image Sensor Unit.
[1]
[1]
4
Disassembly/Assembly > Original Exposure/Feed System (Copyboard Model) > Removing the Contact Image Sensor (Copyboard Model) > Procedure
[A]
F-4-203
F-4-204
Removing the Contact Image Sensor
(Copyboard Model)
■ Preparation
1) Remove the Copyboard Cover (Refer to page 4-75).
2) Remove the Copyboard Glass (Copyboard Model) (Refer to page 4-78).
■ Procedure
CAUTION:
• Do not lose the 2 spacers [1] of the Contact Image Sensor Unit.
• Do not touch the document reading part [A] of the Contact Image Sensor Unit.
[1]
4-80
F-4-205
[A]
F-4-206
4-80