Setting Up Alarms And Warnings - Cisco D9824 Installation And Configuration Manual

Advanced multi decryption receiver
Table of Contents

Advertisement

Chapter 5 Web GUI Setup and Monitoring

Setting up Alarms and Warnings

To Set Up Alarms
1
From the user interface of the D9824, click System Settings > Alarms > Setup.
The Setup - Alarm Setup page is displayed.
2
Select Enable Alarm/Warning Front Panel Reminder and the highest priority
alarm flashes on the LCD display for a two-second interval every 10 seconds.
The alarm will continue to flash periodically until it is either cleared or the
Enable Alarm/Warning Front Panel Reminder is de-selected.
3
Select Enable Video Cutoff on Alarm Condition to cut off the video output if
any enabled alarm is active on the receiver. When video is cut off, there will be
no horizontal or vertical synchronization on the output. This is useful for
downstream redundancy switching by detecting a loss of video signal.
4
Click on the Trap Configuration link to view and/or modify SNMP trap
destinations. The link will open the SNMP page. For more information, see
Setting up SNMP Information and Trap Destinations (on page 190).
5
The Alarm Setup section displays a list of the alarm/fault messages. For more
information on alarm messages, refer to Messages (see "D9824 Alarm Messages"
on page 222).
6
Set Enable/Disable to Yes and the alarm message will be reported. Set to No and
the alarm is disabled and the Relay and Trap settings are ignored.
Note: Enable/Disable must be set to Yes for the Relay and Trap settings to be
functional.
7
If current alarm is enabled, set Trap to Yes and the SNMP trap message will be
sent when the alarm is set or cleared.