Cisco D9824 Installation And Configuration Manual page 217

Advanced multi decryption receiver
Table of Contents

Advertisement

Note: No is a read only value that indicates the setting is Yes, but is currently
being suppressed because the alarm is disabled (Enb is set to No).
8
If current alarm is enabled, set Relay to Yes for the rear panel alarm relay to be
triggered when the alarm is set or cleared.
Note: No is a read only value that indicates the setting is Yes, but is currently
being suppressed because the alarm is disabled (Enb is set to No).
9
Click Apply.
To Set Up Warnings
1
From the Setup - Alarm Setup page, click on the Warning Setup link at the
bottom left hand corner of the page. The Setup - Warning Setup page is
displayed.
2
Select Enable Alarm/Warning Front Panel Reminder and the warning flashes on
the LCD display for a two-second interval every 10 seconds. The warning will
continue to flash periodically until it is either cleared or the Enable
Alarm/Warning Front Panel Reminder is de-selected.
3
The Warning Setup section displays a list of the warning messages. For more
information on warning messages, refer to Messages (see "D9824 Alarm
Messages" on page 222).
4
Set Enable/Disable to Yes and the warning message will be reported. Set to No
and the warning is disabled and the Relay and Trap settings are ignored.
Note: Enable/Disable must be set to Yes for the Relay and Trap settings to be
functional.
78-4039426-01 Rev D