Warning
Message
Type
MCT Timeout # Set
MCT Timeout # Clear
ECT Timeout #
Set
ECT Timeout #
Set
ECT Timeout #
Clear
Memory Usage
Set
Host
Memory Usage
Clear
Host
78-4039426-01 Rev D
Message
Cause/Remedy
mct # is lost
Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning.
If the problem persists,
determine if uplink is
sending the current SI
information table.
Disable the warning if
not using the table.
mct fault cleared
ect # timed out
Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning.
If the problem persists,
determine if uplink is
sending the current SI
information table.
Disable the warning if
not using the table.
ect # is lost
Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning.
If the problem persists,
determine if uplink is
sending the current SI
information table.
Disable the warning if
not using the table.
ect fault cleared
Excessive
Cause: Possible software
(stack/partition)
issue.
memory usage
Remedy: Clear
warnings, reset the unit,
and notify customer
service if the problem
persists.
Normal
(stack/partition)
memory usage
D9824 Alarm Messages
Description
No longer receiving
Inband Control Table.
Event Control Table
was never received.
No longer receiving
Event Control Table.
SW exceeding
allowable memory
usage.
259