D9824 Alarm Messages

The status of the D9824 receiver and its immediate surroundings is reported to the
front panel in the form of messages and alarms. You can enable or disable messages
in the Alarm/Warning settings.
The following table shows an alphabetical list of the available messages and their
default alarm status. The Set Messages and Clear Messages are displayed in the
Warning History when the messages are set or cleared respectively.
Only alarm conditions can be used to trigger rear panel relays to control external
alarm equipment. Warnings are not associated with relay operation.

Alarms

Alarm
Message
Type
PSB non-
Set
compliant
PSB non-
Clear
compliant
222
Message
Cause/Remedy
PROD incomplete
Cause: Production
or PSB non-
command
compliant
exit_weak_state
was not issued
after production
programming was
completed.
Remedy: The
Exit_weak_state
command should
be issued by the
user with PROD
credentials if the
device has not yet
been shipped to
the customer.
Otherwise, the
customer must
reset credentials
using the Front
Panel.
PSB compliant
Description
Severity
Device is in the
Major
WEAK state
after
production
programming
is complete.