O u t put Ass i gnm e nt s

Output Assignments

Address Setting
Module
Number
SW1 SW2 SW3 SW4 SW5
Control Panel
Virtual Outputs
1 =
OFF OFF OFF OFF OFF
2 =
ON OFF OFF OFF OFF
3 =
OFF ON OFF OFF OFF
4 =
ON
ON OFF OFF OFF
5 =
OFF OFF ON OFF OFF
6 =
ON OFF ON OFF OFF
7 =
OFF ON
8 =
ON
ON

Table 20: Address Configuration and Output Assignments

Outputs > Properties >
Event Assignment
(A) = Area Assignment
Assign to Area 1 to 8 (0 = Any Area)
(P) = Control Panel
(Op) = Output Assignment
Assign to Output 1 to 40 (0 = Any Output)
(Zn) = Zone Assignment
Assign to Zone 1 to 144 (0 = Any Zone)
(Ur) = User Assignment
Assign to User 1 to 255 (0 = Any User)
(Tz) = TimeZone Assignment
Assign to TimeZone 1 to 16 (0 = Any TimeZone)
(Dr) = Door Assignment
Assign to Door Assignment 1 to 16 (0 = Any Door)
(Kp) = Keypad Assignment
Assign to Keypad/LAN Reader 1 to 16 (0 = Any
Keypad/LAN Reader)
(Rr) = Reporting Destination
Assign to Destination 1 or 2 (0 = Destination 1 and/
or Destination 2)
(Ma) = Macro Group Assignment
Assign to Macro Group (0 = Any Macro Group)
(CLI) = CLI Trigger Table
Assign to CLI Trigger Table 1 or 2 (0 = Both Tables)
Use [] and [] keys to program which Area, User, Zone,
Keypad or Door Assignment etc you want the output to
follow then press [OK].
Bosch Security Systems 10/22 BLCC615R
Output
Number
1 to 5
6 to 8
9 to 12
13 to 16
17 to 20
21 to 24
25 to 28
29 to 32
ON OFF OFF
33 to 36
ON OFF OFF
37 to 40
MENU 4-1-2
Outputs > Properties >
Output Polarity
00 - Open To Low
01 - Open To Low + Pre
02 - Open Latching Low
03 - Open Pulsing Low
04 - Open 1 Shot Low
05 - 1 Shot Low+Retrigger
06 - 1 Shot Low + Reset
07 - Low To Open
Enter 0 – 15 + [OK] to program the output polarity type.
Each output can only have one polarity type programmed.
Outputs > Properties >
Time Parameter
0 0 0
Hour
0 0 0
The time base parameter is only applicable for output types
that are programmed as one shot or pulsing. Program 0 to
255 for each of the units (Hour, Minute, Seconds and 10th
of a second) for the time parameter. Add the units together
to give the total one shot time or pulsing on/off time.
One S hot M o de
The time base is the length of time that the output will
operate.
For example, you may want a strobe output to operate
for 1 hour, Either of the examples below will achieve the 1
hour time.
Total Time
60 Minutes
60 Minutes
Pul sin g M ode
The time base is the unit of time that the output will pulse
on and off. If the time base is programmed for 60 seconds,
the output will pulse on for 60 seconds and then off for 60
seconds (repeat) until the output is reset.
Solution 6000-IP Quick Start Guide
08 - Low To Open + Pre
09 - Low Latching Open
10 - Low Pulsing Open
11 - Low 1 Shot Open
12 - 1 Shot Open+Retrigger
13 - 1 Shot Open + Reset
14 - Speaker Output
15 - Toggle
0 0 0
0 0 0
Minute
Seconds
Hour
Minute Seconds 10th Sec
001
000
000
060

Table 21: One-Shot Polarity Example

MENU 4-1-3
0 0
MENU 4-1-4
0 0 0
10
Sec
th
000
000
000
000
35