Forced Arming
Arming the system when a zone is not sealed is
known as forced arming. If the system is not armed
and a long beep sounds, forced arming is not
permitted. If this is the case, ensure that all zones are
sealed or manually isolated before arming the system.
4.1

Arming in AWAY Mode

When you leave your premises and require all zones
to be in a ready state to detect intrusion, arm the
system in AWAY Mode. When returning to your
premises, disarm your system (see Section 5.0
Disarming the System) so you do not sound a false
alarm.
There are two different methods for arming the
system in AWAY Mode. One method is standard
and is always available. The other method is optional
and might be disabled by your installer.
To arm in AWAY Mode using the first method:
Enter your user code and press [#] (for example,
[2 5 8 0 #]).
Two beeps sound and the AWAY indicator lights.
Exit time starts.
To arm in AWAY Mode using the second
method:
Hold down [#] until two beeps sound.
The AWAY indicator lights and exit time starts.
4.2

Arming in STAY Mode 1

STAY Mode 1 is only used when the perimeter and
unused areas of the premises must be armed to detect
if an intruder is entering the premises. At the same
time, it allows you to move freely within an area that
is automatically isolated.
Only your security company can
program zones automatically isolated in
STAY Mode 1.
There are two different methods for arming the
system in STAY Mode 1. One method is standard
and is always available. The other method is optional
and might be disabled by your installer.
Entry Guard Timer for STAY Mode 1
When arming the system in STAY Mode 1, an
optional entry timer called Entry Guard Timer for
STAY Mode 1 is available. Use this entry timer to
delay the sirens if a zone is not automatically isolated
and activates an alarm. Entry Guard Timer for STAY
Mode 1 is the delay time used for all zones except
24-hour zones when the system is armed in STAY
Mode 1 or STAY Mode 2.
Bosch Security Systems | 7/05 | F01U009494B
CC404 | Operators Guide | 4.0
If the Entry Guard Timer for STAY Mode 1 is
programmed and a zone not automatically isolated is
activated, the codepad beeps twice per second until
the entry timer expires or the system is disarmed. If
the alarm condition is not reset by entering your user
code and pressing [#] (for example, [2 5 8 0 #])
before the entry timer expires, the sirens sound an
alarm. Only your installer can program this feature.
To arm in STAY Mode 1 using the first method:
Enter your user code and press [*] (for example,
[2 5 8 0 *]).
Two beeps sound and the STAY indicator lights. Exit
time starts counting.
Any zones programmed to be automatically isolated
in STAY Mode 1 flash until exit time expires. At the
end of exit time, all zones selected to be
automatically isolated turn off and the codepad gives
one short beep.
To arm in STAY Mode 1 using the second
method:
Hold down [*] until two beeps sound.
The STAY indicator lights and exit time starts.
Any zones programmed to be automatically isolated
in STAY Mode 1 flash until exit time expires. At the
end of exit time, the zone indicators turn off and the
codepad sounds one short beep.
4.3

Arming in STAY Mode 2

STAY Mode 2 is used only when you want to arm
the perimeter and unused areas of the premises to
detect an intruder while you move freely within an
automatically isolated area. Any Master Code user
can program zones to be automatically isolated in
STAY Mode 2.
Entry Guard Timer for STAY Mode 2
When arming the system in STAY Mode 2, an
optional entry timer called Entry Guard Timer for
STAY Mode 2 is available. Use this entry timer to
delay the sirens if a zone is not automatically isolated,
but activates an alarm. Entry Guard Timer for STAY
Mode 2 is the delay time used for all zones, except
24-hour zones, when the system is armed in STAY
Mode 1 or STAY Mode 2.
If the Entry Guard Timer for STAY Mode 2 is
programmed and a zone not automatically isolated
activates an alarm, the codepad beeps twice a second
until the entry timer expires or you disarm the
system. If you do not reset the alarm by entering
your user code and pressing [#] (for example,
[2 5 8 0 #]) before the entry timer expires, the system
activates the sirens to sound an alarm. Only your
installer can program this option.