Send Test Report; Devices And Optional Modules; Device Status; Keypad Volume - Bosch CC610PB User Manual

Table of Contents

Advertisement

Solution 6000
User Guide
Comms > Periodic Test >

Send Test Report

This menu allows you to test the reporting functions of the
control panel by manually sending a 'Test' report to the
receiving party (i.e. security company monitoring station,
mobile telephone etc).
Enter programming mode (PIN + MENU) then,
1. Enter [MENU] + [5] + [9] + [0].
The keypad will prompt that it is in the process of
sending a test report.
Comms Testing In
Progress ..Please Wait..
Press OK or MENU
If the test is successful, the keypad will prompt:
Comms Test Successful
Press OK or MENU
If the test is NOT successful, the keypad will prompt:
Test Report Failed..
Please Call For Service
Press OK or MENU
2. Press [OK] or [MENU] to exit.

Devices and Optional Modules

Programming options in this section relate to the keypads
and other devices which may be connected to your alarm
system. Your installer will advise you on the exact makeup
and configuration of your system.
34
Devices > Commands >

Device Status

MENU 5-9-0
This option provides a listing of all of the devices and
modules connected to your system. Using this option
it is possible to view the voltage, temperature and other
information about each of the modules.
Enter programming mode (PIN + MENU) then,
1. Press [MENU] + [6] + [0] + [0].
2. Use the [] and [] keys to select the device that you
want to view, then press [OK] to select.
The display will show each parameter for the device
one at a time on the third line of the screen.
4. Press [OK] or [MENU] to exit.
Devices > Commands >

Keypad Volume

This menu allows you to adjust the volume of the keypad's
buzzer. Each keypad will need to have their volume
adjusted separately.
Enter programming mode (PIN + MENU) then,
1. Press [MENU] + [6] + [0] + [7].
The keypad will display:
2. Use the [] and [] keys or use the [] and [] keys
to increase or decrease the volume of the keypad
buzzer until the desired volume has been reached.
3. Press [OK] to save and exit, or press [MENU] to exit
without saving.
Devices > Commands >

Keypad Contrast

This menu allows you to adjust the contrast of the keypad's
LCD display. Each keypad can have their display adjusted
separately.
Kp1 Keypad 1 Name
Kp2 Keypad 2 Name
Ox1 Output Exp 1
Press
OK or MENU

Keypad 1 Name Kp1
Graphic + Prox V2.05
Voltage = 13.87
Press OK or MENU
Keypad 001 Volume
L
Press
OK to
SAVE
Bosch Security Systems 3/23 BLCC610U
MENU 6-0-0
MENU 6-0-7
H
MENU 6-0-8

Advertisement

Table of Contents
loading

This manual is also suitable for:

Solution 6000Cp736bCp737bCm729b

Table of Contents