Reset the System (Cmd 47)

I can perform this command.
I cannot perform this command.
Use this command to reset the system (including fire points) after an alarm. Detection devices, such as smoke detectors and
shock sensors, must be reset after being activated. Resetting the system takes about 20 sec.
If points do not reset, contact your installing company for help.
1.
Ensure your system is off (On indicator is off).
2.
Press [CMD] [4] [7]. The command center may prompt you to enter a valid passcode.
3.
Enter your passcode if necessary. The system resets and the command center displays:
After the system has reset, the command center display automatically returns to the normal display.

Turn Watch On/Off (Cmd 61)

Use the Watch feature to "watch" points when the system is off. For example, parents with small children may want a tone
to sound whenever a door or window is opened as a way of monitoring the location of the children.
Use this command to turn the watch feature on and off.
Once you have programmed the system with points to watch and the responses (see Select Watch Tone on page 31), you
need to turn the watch function on and off.
1.
Ensure your system is off (On indicator is off).
2.
Press [CMD] [6] [1]. The command center may prompt you to enter a valid passcode.
3.
Enter your passcode if necessary. The command center displays the current Watch status (On or Off).
4.
Press [1] to turn Watch On or press [2] to turn Watch Off.
5.
Press [CMD] to exit this feature.