IMPORTANT INFORMATION
5. Inspect:
• Continuity
(with the analog pocket tester (pocket tester))
Analog pocket tester
YU-03112-C
Pocket tester
90890-03112
TIP
• If there is no continuity, clean the terminals.
• When checking the wire harness, perform steps (1) to (3).
• As a quick remedy, use a contact revitalizer available at most part
stores.
HANDLING THE ELECTRONIC PARTS
Electronic parts is very sensitive.
Handle with care and do not give impact.
Mankind has static electricity and it's voltage is very high and elec-
tronic parts is very sensitive.
It has possibility that inside small parts of electronic parts is
destroyed by static electricity.
Do not touch and do not make it dirty.
When you disconnect electronic parts from wire harness, always
turn off main switch.
If you disconnect above condition, it may gives damages to elec-
tronic parts.
1-5
GEN