INSPECTION
BATTERY CURRENT LEAKAGE (DR-Z400E)
Turn the ignition switch to the "OFF" position.
Remove the battery cover. (
Disconnect the - battery lead wire.
Measure the current between the - battery terminal and the -
battery lead wire using the multi circuit tester. If the reading ex-
ceeds the specified value, leakage is evident.
09900-25008: Multi circuit tester set
Tester knob indication: Current (
Battery current (leak): Under 1mA
Because the current leak might be large, turn the
multi circuit tester to the high range, first to avoid
damage to the tester.
Do not turn the ignition switch to the "ON" position
when measuring the current.
When checking to find the excessive current leakage, remove
the couplers and connectors, one by one, checking each part.
REGULATED VOLTAGE (DR-Z400)
Start the engine and run the engine at 5 000 r/min.
Measure the DC voltage between the headlight terminals using
the multi circuit tester. If the tester reads without the specified
value, inspect the generator and regulator/rectifier. (
and 7-11)
09900-25008: Multi circuit tester set
Tester knob indication: Voltage (
Regulated voltage
Standard: 12.5 – 14.0 V at 5 000 r/min
6-2)