7.5 Time to LPM (Low Power Mode)
7.5.1 Time to LPM
By settng the Tme to LPM, the power of the PH Heater s turned on assocated wth the prntng data durng
when the prnter s onlne, and s warmed up to the set temperature. Prntng starts when the temperature
reaches the set value, and s controlled so the temperature s mantaned durng prntng. After prntng s
complete and the Watng status contnues for the set tme, t s automatcally shfted to the Low Power Mode.
The prnter automatcally shfts to the followng status when t enters the Low Power Mode.
Front /Pre Heater = 30°C
PH Heater = 25°C
Meda sucton fan = Off
7.5.2 Setting method
(1) Select [5. Applcaton] from the man menu by usng [▲▼] (Up/Down) keys, and press the [ENTER] key.
Menu
Offline
(2) Select [1.Tme to LPM] from the sub menu by usng [▲▼] (Up/Down) keys, and press the [ENTER] key.
Menu
Offline
(3) To change the value, move the cursor by usng [
(up/down) keys.
Menu
Offline
Settng range: 0000 - 1999 (Default value: 0060): (Unt:mn)
Settng the value to "0000", the Heater stays ON. (Tme to LPM s dsabled).
(4) [Press the [ENTER] key to store the set value.
Press the [ESC] key to cancel the set value. (The mmedately precedng set value s enabled as the
current set value).
● The set temperature cannot be changed durng prntng.
● Only the PH Heater operates n conjuncton wth ths mode. The Front Heater, Platform Heater and Pre
Heater do not operate.
2.Heat Status
+
3.CleaningTool
+
4.Print Para
+
5.Application
+
1.Time to LPM
2.FH and Pre
3.Platform
4.PH Heater
1.Time to LPM
0001
] (left/rght) keys, and change the value by usng [▲▼]