Alarm Type:
Interval:
Owner:
Status:
Note:
When alarm variables exceed the Threshold on the same direction continuously for several times,
an alarm event will only be generated on the first time, that is, the Rising Alarm and Falling Alarm
are triggered alternately for that the alarm following to Rising Alarm is certainly a Falling Alarm and
vice versa.
Specify the type of the alarm.
 All: The alarm event will be triggered either the sampled
value exceeds the Rising Threshold or is under the Falling
Threshold.
 Rising: When the sampled value exceeds the Rising
Threshold, an alarm event is triggered.
 Falling: When the sampled value is under the Falling
Threshold, an alarm event is triggered.
Enter the alarm interval time in seconds.
Enter the name of the device or user that defined the entry.
Enable/Disable the corresponding alarm entry.
240
Return to CONTENTS