TP-Link T1700X-16TS Installation Manual
TP-Link T1700X-16TS Installation Manual

TP-Link T1700X-16TS Installation Manual

Jetstream 12-port 10gbase-t smart switch with 4 10g sfp+ slots
Hide thumbs Also See for T1700X-16TS:

Advertisement

Quick Links

Business Networking Solution

Installation Guide

JetStream 12-Port 10GBase-T Smart Switch
with 4 10G SFP+ Slots
T1700X-16TS

Advertisement

Table of Contents
loading

Summary of Contents for TP-Link T1700X-16TS

  • Page 1: Installation Guide

    Business Networking Solution Installation Guide JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots T1700X-16TS...
  • Page 3 Remind to take notice. The note contains the helpful information for a better use of the product. Related Document The User Guide and CLI Reference Guide of the product are provided on the resource CD. To obtain the latest product information, please visit the official website: http://www.tp-link.com About this Installation Guide...
  • Page 4: Table Of Contents

    JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots Contents Chapter 1 Introduction ——————————— 01 Product Overview ............01 Appearance ...............01 Chapter 2 Installation ——————————— 04 Package Contents ............04 Safety Precautions ............04 Installation Tools ..............06 Product Installation ............07 Chapter 3 Lightning Protection ——————— 09 Cabling Reasonably............09 Connect to Ground ............11 Equipotential Bonding ...........12...
  • Page 5: Chapter 1 Introduction

    You can use Category 5e (CAT 5e) or better Ethernet cable (CAT 6, CAT 6a, or CAT 7) to make 10G connections. TP-Link recommends that you use CAT 6a or CAT 7 cables if the cable distance is greater than 148 feet (45 meters).
  • Page 6 10Gbps. Each has two corresponding Link/Act LEDs , the left one is 10Gbps and the right one is 100/1000Mbps. SFP+ Port Designed to install the SFP module. T1700X-16TS features 4 individual SFP+ ports and supports 1G or 10G SFP module connection. Introduction...
  • Page 7 JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots Rear Panel ■ The rear panel of T1700X-16TS is shown as the following figure. Figure 1-2 Rear Panel of T1700X-16TS Grounding Kensington Security Slot Power Socket Terminal Kensington Security Slot Secure the lock (not provided) into the security slot to prevent the device from being stolen.
  • Page 8: Chapter 2 Installation

    JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots Chapter 2 Installation Package Contents Make sure that the package contains the following items. If any of the listed items is damaged or missing, please contact your distributor. This Installation Guide One Switch One Power Cord Two Mounting Brackets and the...
  • Page 9 JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots Site Requirements ■ Temperature/Humidity 40℃ 0℃ Please keep a proper temperature and humidity in the equipment room. Too high/low humidity may lead to bad insulation, electricity leakage, mechanical property changes and corrosions.
  • Page 10: Installation Tools

    JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots Lightening Protection Extremely high voltage currents can be produced instantly when lightning occurs and the air in the electric discharge path can be instantly heated up to 20,000℃. As this instant current is strong enough to damage electronic devices, more effective lightning protection measures should be taken.
  • Page 11: Product Installation

    JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots Product Installation Desktop Installation ■ To install the device on the desktop, please follow the steps: 1. Set the device on a flat surface strong enough to support the entire weight of the device with all fittings.
  • Page 12 JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots 3. After the brackets are attached to the device, use suitable screws (not provided) to secure the brackets to the rack, as illustrated in the following figure. Figure 2-3 Rack Installation Rack Caution: Please set 5 to 10cm gaps around the device for air circulation.
  • Page 13: Chapter 3 Lightning Protection

    JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots Chapter 3 Lightning Protection Cabling Reasonably In the actual network environment, you may need cable outdoors and indoors, and the requirements for cabling outdoors and indoors are different. A reasonable cabling system can decrease the damage of induced lightning to devices.
  • Page 14: Requirements For Cabling Indoors

    JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots Requirements for Cabling Indoors ■ When cabling indoors, keep a certain distance away from the devices that may cause high-frequency interferences, such as down-conductor cable, powerline, power transformer and electromotor. The main cable should be paved in the metal raceway of the access shaft.
  • Page 15: Connect To Ground

    JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots Min Parallel Cable Pave Way Length (mm) Parallel cabling 2 to 5kVA One is in the grounded metal raceway or metal pipe powerline The both are in the grounded metal raceway or metal pipe Parallel cabling >5kVA...
  • Page 16: Equipotential Bonding

    JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots Note: The grounding bar and the ground cable are not provided with our product. If needed, please self purchase them. Connecting to the Ground via the Power Supply ■ If the device is installed in the normal environment, the device can be grounded via the PE (Protecting Earth) cable of the AC power supply as shown in the following figure.
  • Page 17: Use Lightning Arrester

    JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots The figure below illustrates how to practice equipotential bonding in a network. Figure 3-3 Equipotential Bonding Grounding Terminal Equipotential Bonding Cable Ground Cable Grounding Bar When equipotential bonding, please note that the cable should be copper wrapped Kelly with its area being 6mm at least.
  • Page 18 JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots When purchasing or using a signal lightning arrester, please observe the following rules: The port rate of the signal lightning arrester should match the rate of the desired port ■ on the device.
  • Page 19: Chapter 4 Connection

    JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots Chapter 4 Connection Ethernet Port Connect a Ethernet port of the switch to the computer by RJ45 cable as the following figure shows. Figure 4-1 Connecting the RJ45 Port RJ45 Port RJ45 Cable SFP+ Port Connect an SFP/SFP+ transceiver or an SFP+ cable to the SFP+ port.
  • Page 20: Power On

    JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots The power socket, device and rack are well grounded. ■ The device is correctly connected to other network devices. ■ Power On Plug in the negative connector of the provided power cord into the power socket of the device, and the positive connector into a power outlet as the following figure shows.
  • Page 21: Chapter 5 Configuration

    JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots Chapter 5 Configuration Configure the Switch via GUI 1. To access the GUI of the switch, open a web browser and t ype the default management address http://192.168.0.1 in the address field of the browser, then press the Enter key.
  • Page 22: Configure The Switch Using Cli

    JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots 3. After a successful login, the main page will appear as the following figure, and you can configure the function by clicking the setup menu on the left side of the screen. Figure 5-3 Main Page of the Switch Configure the Switch Using CLI...
  • Page 23 JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots 3. Type telnet 192.168.0.1 in the command prompt shown as Figure 5-5, and press the Enter button. Figure 5-5 Connecting to the Switch 4. Type the default user name and password (both of them are admin), then press the Enter button so as to enter User EXEC Mode.
  • Page 24: Appendix A Troubleshooting

    JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots Appendix A Troubleshooting Q1. What could I do if I forgot the username and password of the switch? Press the Reset button for at least 5 seconds to reset the system. The system will be reset to the factory default settings, and the default login user name and password are both admin.
  • Page 25: Appendix B Specifications

    JetStream 12-Port 10GBase-T Smart Switch with 4 10G SFP+ Slots Appendix B Specifications Item Content IEEE802.3u, IEEE802.3ab, IEEE802.3ad, IEEE802.3ae, IEEE802.3an, IEEE802.3z, Standards IEEE802.3x, IEEE802.1ab, IEEE802.1p, IEEE802.1q, IEEE802.1x, IEEE802.1d, IEEE802.1s, IEEE802.1w 100Base-TX 2-pair UTP/STP of Cat. 5 or above (maximum 100m) 1000Base-T 4-pair UTP/STP of Cat.
  • Page 26: Fcc Statement

    FCC STATEMENT This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
  • Page 27: Bsmi Notice

    BSMI Notice 安全諮詢及注意事項 • 請使用原裝電源供應器或只能按照本產品注明的電源類型使用本產品。 • 清潔本產品之前請先拔掉電源線。 請勿使用液體、 噴霧清潔劑或濕布進行清潔。 • 注意防潮, 請勿將水或其他液體潑灑到本產品上。 • 插槽與開口供通風使用, 以確保本產品的操作可靠並防止過熱, 請勿堵塞或覆蓋開口。 • 請勿將本產品置放於靠近熱源的地方。 除非有正常的通風, 否則不可放在密閉位置中。 • 請不要私自打開機殼, 不要嘗試自行維修本產品, 請由授權的專業人士進行此項工作。 此為甲類資訊技術設備, 于居住環境中使用時, 可能會造成射頻擾動, 在此種情況下, 使用者會被要求採取某些適 當的對策。 Industry Canada Statement CAN ICES-3 (A)/NMB-3(A) Explanation of the symbols on the product label Symbol Explanation AC voltage...
  • Page 28 Website: http://www.tp-link.com Tel: +86 755 26504400 E-mail: support@tp-link.com © 2016 TP-Link 7106506816 REV2.0.0...

Table of Contents