Prerequisite
All configurations of the association between an EFM OAM session and an interface are
complete.
Procedure
Step 1 Run the display this command in the OAM management view to check whether an EFM OAM
session and an interface are successfully associated.
----End
Example
Run the display this command. You can view all associations between EFM OAM sessions and
interfaces.
[Quidway-oam-mgr] display this
#
oam-mgr
oam-bind ingress interface XGigabitEthernet0/0/1 egress efm interface
XGigabitEthernet0/0/2 trigger if-down
oam-bind ingress efm interface XGigabitEthernet0/0/2 trigger if-down egress
interface XGigabitEthernet0/0/1
#
return

4.8 Maintaining Ethernet OAM

This section describes how to maintain Ethernet OAM. Detailed operations include deleting
CCM statistics, monitoring Ethernet OAM.
4.8.1 Debugging EFM OAM
After debugging, you need to disable the debugging function in time.
Context
Debugging affects the performance of the system. So, after debugging, run the undo debugging
all command to disable it immediately.
When an EFM OAM fault occurs, run the following debugging command in the user view to
view the debugging information to locate and analyze the fault.
Issue 01 (2011-07-15)
CAUTION
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
4 Ethernet OAM Configuration-EFM