Optional) Detecting Errored Codes Of Efm Oam - Huawei Quidway S6700 series Configuration Manual

Hide thumbs Also See for Quidway S6700 series:
Table of Contents

Advertisement

Quidway S6700 Series Ethernet Switches
Configuration Guide - Reliability
Context
Do as follows on the devices at one end or both ends of the link:
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
interface interface-type interface-number
The interface view of an interface at one end of the link is displayed.
Step 3 Run:
efm error-frame period period
The period for detecting errored frames on the interface is set.
By default, the period for detecting errored frames on an interface is 1 second.
Step 4 Run:
efm error-frame threshold threshold
The threshold for detecting errored frames on the interface is set.
By default, the threshold for detecting errored frames on an interface is 1.
Step 5 Run:
efm error-frame notification enable
The interface is enabled to detect errored frames.
By default, an interface cannot detect errored frames.
----End

4.4.3 (Optional) Detecting Errored Codes of EFM OAM

When an interface is enabled to detect errored codes, the S6700 generates an errored code event
and notifies the peer, if the number of errored codes reaches or exceeds the threshold within a
set period.
Context
Do as follows on the devices at one end or both ends of the link:
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
interface interface-type interface-number
Issue 01 (2011-07-15)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
4 Ethernet OAM Configuration-EFM
157