Configuration Guide - Reliability
Data Preparation
To complete the configuration, you need the following data:
l
l
l
Procedure
Step 1 Enable EFM OAM globally.
# Enable EFM OAM globally on Switch A.
<Quidway> system-view
[Quidway] sysname SwitchA
[SwitchA] efm enable
# Enable EFM OAM globally on Switch B.
<Quidway> system-view
[Quidway] sysname SwitchB
[SwitchB] efm enable
Step 2 Configure EFM OAM on XGE 0/0/1 of Switch A to work in passive mode.
[SwitchA] interface xgigabitethernet 0/0/1
[SwitchA-XGigabitEthernet0/0/1] efm mode passive
[SwitchA-XGigabitEthernet0/0/1] bpdu enable
Step 3 Enable EFM OAM on XGE 0/0/1 of Switch B and XGE 0/0/1 of Switch A.
# Enable EFM OAM on XGE 0/0/1 of Switch A.
[SwitchA-XGigabitEthernet0/0/1] efm enable
[SwitchA-XGigabitEthernet0/0/1] quit
# Enable EFM OAM of XGE 0/0/1 on Switch B.
[SwitchB] interface xgigabitethernet 0/0/1
[SwitchB-XGigabitEthernet0/0/1] efm enable
[SwitchB-XGigabitEthernet0/0/1] bpdu enable
Step 4 Configure XGE 0/0/1 of Switch B to detect the errored frames, errored codes, and errored frame
seconds.
# Configure XGE 0/0/1 of Switch B to detect the errored frames.
[SwitchB-XGigabitEthernet0/0/1] efm error-frame period 5
[SwitchB-XGigabitEthernet0/0/1] efm error-frame threshold 5
[SwitchB-XGigabitEthernet0/0/1] efm error-frame notification enable
# Configure XGE 0/0/1 of Switch B to detect the errored codes.
[SwitchB-XGigabitEthernet0/0/1] efm error-code period 5
[SwitchB-XGigabitEthernet0/0/1] efm error-code threshold 5
[SwitchB-XGigabitEthernet0/0/1] efm error-code notification enable
# Configure n XGE 0/0/1 of Switch B to detect the errored frames seconds.
[SwitchB-XGigabitEthernet0/0/1] efm error-frame-second period 120
[SwitchB-XGigabitEthernet0/0/1] efm error-frame-second threshold 5
Issue 01 (2011-07-15)
Period for detecting errored frames on XGE 0/0/1 of Switch B (5 seconds) and threshold
of number of errored frames (5)
Period for detecting errored codes on XGE 0/0/1 of Switch B (5 seconds) and threshold of
number of errored codes (5)
Period for detecting errored frame seconds on XGE 0/0/1 of Switch B (120 seconds) and
threshold of number of errored frame seconds (5)
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
4 Ethernet OAM Configuration-EFM