Locking Data Flows On The Master Interface; Locking Data Flows On The Slave Interface - Huawei Quidway S6700 series Configuration Manual

Hide thumbs Also See for Quidway S6700 series:
Table of Contents

Advertisement

Quidway S6700 Series Ethernet Switches
Configuration Guide - Reliability

2.3.2 Locking Data Flows on the Master Interface

Context
If data flows are locked on the master interface, they cannot be switched to the slave interface
automatically when the master interface fails. As a result, traffic is interrupted.
Do as follows on SwitchD shown in
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
smart-link group group-id
The Smart Link group view is displayed.
Step 3 Run:
smart-link lock
Data flows are locked on the master interface.
----End

2.3.3 Locking Data Flows on the Slave Interface

Context
If data flows are locked on the slave interface, they cannot be switched to the master interface
automatically when the slave interface fails. As a result, traffic is interrupted.
Do as follows on SwitchD shown in
Procedure
Step 1 Run:
system-view
The system view is displayed.
Step 2 Run:
smart-link group group-id
Issue 01 (2011-07-15)
CAUTION
CAUTION
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
2 Smart Link and Monitor Link Configuration
Figure
2-2.
Figure
2-2.
26