Quidway S6700 Series Ethernet Switches
Configuration Guide - Reliability
The OAM management view is displayed.
Step 3 Run:
oam-bind ingress efm interface interface-type1 interface-number1 trigger if-down
egress interface interface-type2 interface-number2
The unidirectional transmission of fault information from an EFM OAM session to an interface
is configured.
When the EFM OAM session detects a fault, the physical status of the interface associated with
the EFM OAM session becomes Down.
interface interface-type1 interface-number1 specifies the interface enabled with EFM OAM.
interface interface-type2 interface-number2 specifies the interface associated with the EFM
OAM session.
Step 4 Run:
oam-bind ingress interface interface-type1 interface-number1 egress efm interface
interface-type2 interface-number2 trigger if-down
The unidirectional transmission of fault information from an interface to an EFM OAM session
is configured.
When an interface associated with an EFM OAM session goes Down, the OAM management
module can send fault information to the EFM OAM session associated with the interface, and
then the EFM OAM session sends the fault information to the remote device.
interface interface-type1 interface-number1 specifies the interface associated with the EFM
OAM session.
interface interface-type2 interface-number2 specifies the interface enabled with EFM OAM.
Step 5 Run:
oam-bind efm interface interface-type1 interface-number1 trigger if-down interface
interface-type2 interface-number2
The bidirectional transmission of fault information between an EFM OAM session and an
interface is configured.
interface interface-type1interface-number1 specifies the interface enabled with EFM OAM.
interface interface-type2 interface-number2 specifies the interface associated with the EFM
OAM session.
----End
4.7.3 Checking the Configuration
After the association between an EFM OAM session and an interface is successfully configured,
you can view the association configuration in the OAM management view.
Issue 01 (2011-07-15)
NOTE
If Step 5 is performed, both the oam-bind ingress efm interface md-name ma ma-name trigger if-
down egress interface interface-type interface-number command and the oam-bind ingress interface
interface-type interface-number egress cfm md md-name ma ma-name trigger if-down command are
displayed in the configuration file, indicating fault notification in opposite directions.
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
4 Ethernet OAM Configuration-EFM
171