Datamax a-class mark ii Operator's Manual page 122

Hide thumbs Also See for a-class mark ii:
Table of Contents

Advertisement

Displayed Message
HEAD CLEANING FAULT
OUT OF STOCK
POSITION FAULT
PRINT ENGINE FAULT
RAM FAULT
112
Fault Messages (continued)
Description
Scheduled cleaning has
exceeded three times the
selected distance.
The printer cannot detect
the presence of media.
Possible causes include a
firmware update, a power
failure or reset during a
ribbon, out of stock or TOF
fault, and incomplete
calibrations.
A problem within the print
logic has been detected.
A memory failure has been
detected.
Possible Solution(s)
Clean the printhead (see Section
5.6.1).
Examine the printer for media
then proceed accordingly:
If the printer is out of
stock, load media; or,
If stock is loaded, ensure
that the Media Sensor is
calibrated (see Section
3.4), properly positioned
(see Section 3.2) and, if
the media has large gaps
that the PAPER OUT
DISTANCE is adjusted (see
Section 4.2.1).
Press the FEED Key in an
attempt to identify and then
clear the fault. Perform
calibration (see Section 3.4).
Cycle printer power OFF and ON.
If the fault does not clear, call
for service.
Cycle printer power OFF and ON.
If the fault does not clear, call
for service.