Step
Action
In the table, where both
the Label Value and TOF
Value are at least 20,
subtract the amounts and
record the result as a
Difference Value (see
K
below).
Identify the largest
Difference Value and then
the corresponding Gain
Number.
Gain Number
Step
Action
Scroll to the Gain Number
determined in the
L
previous step and then
press the ENTER Key.
(continued)
80
Displayed Message
*31
<yyy>
- Or, for reflective media:
*31
<yyy>
Sample Calibration Table
Label Value
00
252
01
250
02
248
...
...
15
188
16
184
17
179
18
174
19
170
...
...
31
132
Displayed Message
*18
<yyy>
- Or, for reflective media:
*18
<yyy>
GAIN TRAN
(0 - 31)
GAIN REFL
(0 – 31)
TOF Value
248
245
234
...
63
51
38
25
19
...
14
GAIN TRAN
(0 - 31)
GAIN REFL
(0 – 31)
Comment
In this example, Gain
Number 18 is chosen
because, where both
values are at least
twenty, it has the
highest Difference
Value.
This Gain Number will
be used to resample
the media.
Difference Value
4
5
14
...
125
133
141
149
N/A
...
N/A
Comment
After ENTER is pressed,
an asterisk (*) appears
to denote selection.