LCD Screen

The LCD screen is the primary user input/output information center. Parameter settings may be viewed or
changed using the LCD display unit of the EOI. To view or change a parameter setting using the LCD
screen, press the Mode key until the Program menu is displayed. Turn the Rotary Encoder until the
desired Primary Menu item (see
the item from the Primary Menu (repeat the press-to-select for submenu items).
See the section titled
settings.
Upon reaching the desired parameter selection, the current setting may be viewed, or selected and changed
by pressing the Rotary Encoder and the setting will take on the reverse video format (dark background/
light text). Turn the Rotary Encoder to change the parameter setting. Press the ESC key while the new
parameter setting is in the reverse video mode to exit the selection without saving the change or press the
Rotary Encoder while the parameter setting is in the reverse video mode to accept the change.
Repeated ESC key entries at any time takes the menu back one level each time the ESC key is pressed
until the Frequency Command screen is reached. Further ESC entries will toggle the system to and from
the Frequency Command screen and the EOI Command menu.
Note:
Changes carried out from the EOI Command screen will be effective for EOI-
controlled ASD operation only. See the section titled
further information on

Primary Menus of the LCD Screen

The three primary screens of the LCD screen are displayed while accessing the associated operating
mode: the Frequency Command, Monitor, and the Program Menu screens.
Figure 22. Frequency Command Screen.
Speed Reference %
Speed Reference Hz
User-Selected
Monitored Parameters (see
Main Monitor Selections on pg.
Discrete I/O Terminal Status Or
Alarm Condition
Figure 23. Monitor Screen (see
Screen Name
Active Frequency
Command
Active DC Bus Voltage
Figure 24. Program Menu Screen (see
Screen Name
Primary Menu Items
32
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
pg.
46) is within the cursor block. Press the Rotary Encoder to select
Default Setting Changes on pg. 74
EOI Command Mode
45)
pg. 43
for more on the Monitor screen items).
Monitor
Freq At Trip:
Freq Ref:
Output Current:
DC Voltage:
Output Voltage:
pg. 46
Program
{
Startup Wizard...
Fundamental...
Terminal...
Direct Access...
Utilities...
for more information on changing parameter
EOI Command Mode on pg. 42
operations.
Not-Ready-to-Run
Indicator (ST-to-CC required)
Ready-to-Run Indicator
Appears When ST is Connected
to CC
Forward Run Active
Reverse Run Active
Item Number 1 of 43
01:43
Monitored items
(Only 5 Items Listed)
Speed at Trip (If Applicable)
0.00Hz
0.00Hz
Active Output Current
0.00%
0.00%
ASD Output Voltage
0.00%
for more on the Program Menu Screen).
01:15
Item Number 1 of 15
Program Menu items
(Only 5 Items Listed)
H9 ASD Installation and Operation Manual