Toshiba H9 ASD Installation And Operation Manual page 215

Adjustable low voltage heavy duty industrial speed drive
Hide thumbs Also See for H9 ASD:
Table of Contents

Advertisement

F831
Communications Option (DeviceNet/Profibus) Setting 2
Program Communications Communication Settings
While using the DeviceNet/Profibus communications protocol, parameters
F831
F836
allow the user to select the ASD memory location that holds the
Command/Frequency/Monitoring instructions to be applied to the ASD for
Communications Option Settings 2 – 7, respectively.
See the DeviceNet Option Instruction Manual (P/N 58683) for more
information on this parameter.
Settings:
0 — Disabled
1 — FA06 (ALCAN Command 1)
2 — FA23 (ALCAN Command 2)
3 — FA07 (ALCAN Frequency Command, 0.01 Hz)
4 — FA33 (Torque Command, 0.01%)
5 — FA50 (Terminal Output)
6 — FA51 (Analog Output Data from Comm. [FM])
7 — FA52 (Analog Output Data from Comm. [AM])
8 —
F601
(Stall Prevention Level, %)
9 —
F441
(Power Running Torque Limit 1 Level, 0.01%)
10 —
F443
(Regen. Braking Torque Limit 1 Level, 0.01%)
11 —
F460
(Speed Loop Proportional Gain)
12 —
F461
(Speed Loop Stabilization Coefficient)
Communications Option (DeviceNet/Profibus) Setting 3
Program Communications Communication Settings
Same as F831. See
F831
Communications Option (DeviceNet/Profibus) Setting 4
Program Communications Communication Settings
Same as F831. See
F831
Communications Option (DeviceNet/Profibus) Setting 5
Program Communications Communication Settings
Same as F831. See
F831
Communications Option (DeviceNet/Profibus) Setting 6
Program Communications Communication Settings
Same as F831. See
F831
Communications Option (DeviceNet/Profibus) Setting 7
Program Communications Communication Settings
Same as F831. See
F831
208
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
for information on this parameter
for information on this parameter
for information on this parameter
for information on this parameter
for information on this parameter
Direct Access Number — F831
Parameter Type — Selection List
Factory Default — 0000h
Changeable During Run — Yes
Direct Access Number — F832
Parameter Type — Selection List
Factory Default — 0000h
Changeable During Run — Yes
Direct Access Number — F833
Parameter Type — Selection List
Factory Default — 0000h
Changeable During Run — Yes
Direct Access Number — F834
Parameter Type — Selection List
Factory Default — 0000h
Changeable During Run — Yes
Direct Access Number — F835
Parameter Type — Selection List
Factory Default — 0000h
Changeable During Run — Yes
Direct Access Number — F836
Parameter Type — Selection List
Factory Default — 0000h
Changeable During Run — Yes
H9 ASD Installation and Operation Manual
F836

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

P9 asd

Table of Contents