F515

Deceleration Time 4

Program Special Accel/Decel 1 – 4 Settings
This parameter specifies the time in seconds for the output of the ASD to go
from the Maximum Frequency to 0.0 Hz for the 4 Deceleration profile. The
Accel/Decel pattern may be set using F502. The minimum Accel/Decel time
may be set using F508.
Note:
A deceleration time shorter than the load will allow may cause
nuisance tripping and mechanical stress to loads. Automatic
Accel/Decel, Stall, and Ridethrough settings may lengthen the
deceleration times.

Acceleration/Deceleration Pattern 4

Program Special Accel/Decel 1 – 4 Settings
This parameter enables a user-selected preprogrammed output profile that
controls the acceleration and deceleration pattern for the 4 Accel/Decel
parameter.
Settings:
0 — Linear
1 — S-Pattern 1
2 — S-Pattern 2

Acceleration/Deceleration Switching Frequency 3

Program Special Accel/Decel Special
This parameter sets the frequency at which the acceleration control is switched
from the Accel 3 profile to the Accel 4 profile during a multiple-acceleration
profile configuration.
Pattern Operation Selection
Program Pattern Run Pattern Run
Pattern Run operation is enabled by selecting Seconds or Minutes as a unit of
measure for the Operation Time setting for the selected Preset Speeds.
See Parameter
F523
for more information on Selections and Group Speeds
setup.
Settings:
0 — Disabled
1 — Enabled (Units in Seconds)
2 — Enabled (Units in Minutes)
Pattern Operation Mode
Program Pattern Run Pattern Run
This parameter sets the start condition of subsequent Pattern Runs after the
initial Pattern Run has been terminated or has completed its programming.
Settings:
0 — Reset After Stop
1 — Continue After Stop
170
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Direct Access Number — F515
Parameter Type — Numerical
Factory Default — (ASD-Dependent)
Changeable During Run — Yes
Minimum — 0.1
Maximum — 6000
Units — Seconds
Direct Access Number — F516
Parameter Type — Selection List
Factory Default — Linear
Changeable During Run — Yes
Direct Access Number — F517
Parameter Type — Numerical
Factory Default — 0.00
Changeable During Run — Yes
Minimum — 0.00
Maximum — Max. Freq. (F011)
Units — Hz
Direct Access Number — F520
Parameter Type — Selection List
Factory Default — Disabled
Changeable During Run — No
Direct Access Number — F521
Parameter Type — Selection List
Factory Default — Reset After Stop
Changeable During Run — No