F951
Input Function Target 3
Program My Function My Function Unit 6
This parameter plays a role in the setup of the My Function feature by
selecting the functionality of the programmable Input Function Target 3
terminal.
This setting assigns the function of the programmable Input Function Target 3
terminal to any one of the user-selectable functions listed in
Table 8 on pg.
239, or
See
F977
for more information on this parameter.
Output Function Assigned
Program My Function My Function Unit 6
This parameter plays a role in the setup of the My Function feature by
selecting the functionality of the Output Function Assigned terminal.
This setting assigns the function of the programmable Output Function
Assigned data location to one of the functions listed in the Input Setting field
of
Table 8 on pg.
239.
Settings:
0 – 3099
See the My Function Instruction Manual (P/N E6581335) and
information on this parameter.
Input Function Target 1
Program My Function My Function Unit 7
This parameter plays a role in the setup of the My Function feature by
selecting the functionality of the programmable Input Function Target 1
terminal.
This setting assigns the function of the programmable Input Function Target 1
terminal to any one of the user-selectable functions listed in
Table 8 on pg.
239, or
See
F977
for more information on this parameter.
Input Function Command 1
Program My Function My Function Unit 7
This parameter is used to assign a user-selected logical operator to two user-
selected Input Function Target variables, enable a counter/timer function, or
perform a hold/reset function.
Table 11 on pg. 243
lists the available selections. Their use and selection
requirements are described in an example at F977.
224
Phone: 800.894.0412 - Fax: 888.723.4773 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Table 10 on pg.
241.
Table 10 on pg.
241.
Direct Access Number — F951
Parameter Type — Selection List
Factory Default — 0 (Disabled)
Changeable During Run — Yes
Table 7 on pg.
238,
Direct Access Number — F952
Parameter Type — Selection List
Factory Default — 0 (Disabled)
Changeable During Run — Yes
F977
for more
Direct Access Number — F953
Parameter Type — Selection List
Factory Default — 0 (Disabled)
Changeable During Run — Yes
Table 7 on pg.
238,
Direct Access Number — F954
Parameter Type — Selection List
Factory Default — 0 (NOP)
H9 ASD Installation and Operation Manual
F954